Diagnostic

Computerized Tonometer CT-80

CT-80

Dual sensor system assures high-level measurement of intraocular pressure

  • Dual Sensor System
    TOPCON's Accurate Measuring System

    The TOPCON CT-80 takes its original measurement method using two sensors; one for light and one for pressure.When the air puff applanates the cornea a light sensor detects the applanation moment, while at the same time another sensor monitors the internal chamber to obtain the intraocular pressure.
  • Triple Safety Function
    A Focus on Safety

    The CT-80 features an innovative triple safety function. First, an adjustable safety stopper may be set by the operator.Second, a “too close” display on the monitor guides the user in alignment. Third, an audible warning buzzer informs the operator if the cornea and the instrument are too close.
  • 30% Faster Interval Time
    Fast and Easy Measurements

    The CT-80 provides easier and faster operation with the aid of a new alignment bar and an improved air cylinder. The interval between measurements has been reduced by over 30%, so that patients may be examined more comfortably in a shorter period of time. Once the alignment has been completed, the resulting data are automatically measured and displayed.
  • Built-in Self Check Function
    The CT-80 lets the operator know in advance when maintenance is needed. It displays a warning message on the monitor when a lens is dirty, and also which lens it is (the measurement glass or the chamber glass).
<Specifications>
Model CT-80
Measurement Range 0-60mmHg [0-30mmHg/0-60mmHg (Selectable)]
Working Distance 11mm
Measurement Display TV Monitor Screen
  • R/L change over --- automatically detected and displayed.
  • Up to three measurement of each eye can be displayed and printed out.
Measurement Recording Built-in printer
Measurement Mode Auto/Manual (selectable)
Alignment When the alignment luminous spots are within the inner alignment mark,
  • In Auto Mode:
    measurement is automaticaly activated
  • In Manual Mode:
    alignment will change from a broken box to a solid pattern when proper alignment is achieved, and depressing the switch on the omni-directional joystick activates the measuring cycle.
Error Indication When the measurement signal is not strong enough, IOP value is indication in () or just ‘ERR’ is displayed.
Adjustable Safety Stopper Minimum distance between the front of the instrument and the patient can be established in advance.
Operating Temperature 10°C to 40°C
Base Travel 44mm (back & forth) / 88mm (left & right) / 28mm (vertically)
Chinrest Vertical Travel 68mm
External Output Terminal RS-232C
Power Supply AC 100-120V, 220-240V, 50/60Hz
Power Consumption 80VA (“Auto-shut-off”: power saving mechanism adopted)
Dimensions 272(W) × 505(D) × 430-458(H)mm
Weight Approx. 18kg

△pagetop