Optical Coherence Tomography 3D OCT-2000
More Advanced - Topcon 3D OCT
Our new 3D OCT-2000 has many new features including the latest OCT imaging software to provide crystal clear images, analysis modules to provide the detailed information required by the doctor and is still the only OCT that combines a high resolution non-mydriatic retinal camera with a OCT .
The Topcon 3D OCT-2000 is a valuable diagnostic tool for the detection and monitoring of glaucoma, diabetic retinopathy, age-related macular degeneration and more !
The Combination of OCT & Non-mydriatic Retinal Camera
The Topcon 3D OCT-2000 is the only fourier domain OCT that includes a high resolution non-mydriatic retinal camera.
You can acquire a high resolution color fundus image and an OCT image simultaneously.


High-resolution OCT
With years of experience in retinal imaging and a passion to produce the highest quality results, we have succeeded in producing our most stunning retinal image ever an overlap of up to 50! With just one click to change the reference mirror position to the choroidal mode, the border between choroid and sclera becomes apparent due to Enhanced Depth Imaging. Trust our newest of 3D OCT-2000 for better visualization and differentiation of each single layer.

Easy Operation
With the combined multiple auto functions, no extra training is required to use Topcon 3D OCT-2000.
Images can be captured easily, accurately and immediately.
- Easy Capturing
- Intuitive scan protocol selection with auto functionality will increase workflow. You will be assisted with Auto Focus / Auto Shoot for retinal camera and Auto Focus / Auto Z&Z Lock / Auto Polarisation when shooting OCT.


- Easy To Use Touch-Screen Panel
- 8.4” integrated touch screen LCD control panel for easy operation.
Less eye movement when picturing, since you can both navigate and picture by one screen without seeing the PC monitor every time.
Variable Analysis Modules
- Compare Function
- Exclusive 3D OCT FastMap™ software allows for dynamic visualisation of each eye on the same screen or serial exams from the same eyes.
- The built in analysis tools illustrate the extent of oedema pre and post treatment, allowing simplistic methods to plan clinical care and track medical effectiveness.

- 8.2×3mm Wide View
- 3D OCT-2000 allows for wide area scans, allowing even the smallest area of pathology to be captured during initial scan.

- Combination of Topcon 3D OCT & FA/FAF/ICG Images and More
- Autofluorescence, Fluorescence Angiography and Indocyanine Green image is simply imported to allow pin point registration to aid the diagnosis of RPE and Choroidal changes.

- 3D Tracking
- The 3D tracking system (compensation function and rescanning function) reduces blurred images generated by the microsaccades, enabling you to obtain consistent quality images.
- ■Compensation Function
- Automatically corrects the distortion due to microsaccades
- ■Rescanning Function
- Automatically compensates by rescanning the area when microsaccades cause interference
- RNFL Trend Analysis
-
- □Change in RNFL Thickness
- Change in the nerve fibre layer thickness can be monitored via RNFL Trend Analysis and comparison with normative data. Multiple patient visits can be viewed simply on one screen aiding disease management.
- □Trend Analysis
- Trend analysis can calculate linear regression lines by using all stored patient data. This chart can be useful to follow patient data as well as a useful patient education tool.
- □Select an Icon
- Total patient history data including overlay / thickness map / fundus image can now be shown on the same report.
- Disc Topography Module
- Comprehensive normative database comparisons combined with C / D ration and topography maps can be displayed and analysed on a single screen or report.
- Panoramic Fundus View
- The mosaic function enables easy assessment of a vast area from macula to disc, providing a broader view of the fundus which can lead to faster detection and treatment for patients.

- Angle Measurement Function
- With automatic calculation, chamber angle measurement is quick and simple.
- ※ Only line scan can support this tool.
- ※ For printout, screen capture is available.
■Get Quickly, Non-contact, High-resolution Anterior Image
Topcon 3D OCT-2000 not only gives you the posterior but also an anterior image, unmasking the precise shape and curvature of the cornea. Combined with rich analysis modules, you can easily detect any corneal disorders, such as corneal trauma, ulcer, astigmatism the rich analysis module is also good for pre and post refractive surgery observation.
Enjoy increased clinical efficiency with the enhanced Topcon 3D OCT.

※Courtesy of Dr.Frederique Matonti
Specifications
| Observation & Photographing of Fundus | ||
|---|---|---|
| Picture Angle | 45° | |
| Operating Distance | 40.7mm (in fundus photography) 63.7mm (in anterior segment photography)* |
|
| Photographable Diameter of Pupil | ||
| Retinal Camera | 45°:φ4.0mm or more Small pupil diameter:φ3.3mm or more |
|
| Optical Coherence Tomography | φ2.5mm or more | |
| Observation & Photographing of Fundus / Anterior Segment Tomogram | ||
| Scan Patterns (Recommended)** | Macula:3D Scan | 512×128 ( 128 horizontal scan lines comprised of 512 A-scans ), 6×6mm |
| Macula:Radial Scan | 1024×6 or 12 ( 6 or 12 radial scan lines comprised of 1024 A-scans ), 6mm | |
| Disc:3D Scan | 512×128 ( 128 horizontal scan lines comprised of 512 A-scans ), 6×6mm | |
| Disc:Circle Scan | φ3.4mm, 1024 A-scans | |
| 7 Line Raster | 1024×7 (1024 A-scans per B-scan×7), 6mm | |
| Scan Speed | 27,000 A-scans per second | |
| Scanning Range (On Fundus) | 8.2×3mm, 6×6mm, 4.5×4.5mm, 3×3mm | |
| (On Cornea)* | 6×6mm , 3×3mm | |
| Lateral Resolution | ≦20μm | |
| In-depth Resolution | 5μm ~ 6μm | |
| Observation & Photographing of Fundus Image / Fundus Tomogram | ||
| Internal Fixation Target |
Matrix LCD (The display position can be changed and adjusted. The presenting method can be changed. ) |
|
| Power Source / Supply | ||
| Power Source | Voltage:100/110/120/220/230/240V | |
| Frequency:50-60Hz | ||
| Power Supply | 200VA (max 400VA) | |
| Dimensions / Weight | ||
| Dimensions | W545mm× D535mm × H600-630mm | |
| Weight | 35kg | |
* With anterior segment attachment.
** More variable scan patterns available with a combination of different pixel and scan range.