Retinal Camera TRC-NW7SF MARKⅡ
Retinal camera TRC-NW7SF MARKⅡ


- Mydriatic and Non mydriatic retinal camera in a single unit
- High resolution 6.5" LCD monitor
- Built in digital camera
- Seamless connectivity with IMAGEnet™

■Easy to view
TRC-NW7SF MarkⅡ incorporates a tilting 6.5 inch color LCD monitor. Alignment and focusing are performed through the monitor without the need of a viewfinder. Alignment in all image types can be viewed as a live image.
■Easy focus & alignment
Focus and alignment are easily achieved by split vertical bars and Topcon's original working distance dots

■IR illumination
TRC-NW7SF MarkⅡ employs IR illumination for alignment and focusing to assure patient comfort.
■9 point internal fixation LEDs
TRC-NW7SF MarkⅡ incorporates 1 central point and 8 peripheral fixation points. All points are shifted easily on a touch panel and provide 80 degrees of retinal coverage.
■Touch panel operation
An easy to use colorful touch panel allows the user to configure the cameras settings, such as photo mode, flash intensity, etc at the touch of a finger. Suitable settings for each photo type are applied automatically.
■Exposure Assistance
Retinal photography with digital camera is sensitively affected by flash intensity. Optimum flash intensity is automatically detected and suitable exposure assured every time.
■Built-in Printer
Topcon's 3.15M pixels digital camera is built in. With its easy-to-use control panel, switching between PC/still/live modes and other operational setting can be done quite easily. It captures live images as digital data and transfers direct to PC via USB2. Timer, R/L eye detection, angle and patient data will also be transferred with images directly into IMAGEnet™.

■Swing and Tilt
TRC-NW7SF MARKⅡ incorporates a swing and tilt mechanism as would be expected of a good Mydriatic fundus camera. This allows viewing of peripheral segments without moving the patient’s head or fixation.

Camera Option
Digital single lens reflex camera option is available (for color and Fluorescein).
Option should be specified when ordered.

IMAGEnet new Features
Digital Handshaking
The TOPCON TRC-NW7SF MARKⅡ features several unique capabilities which enhance its use, increase convenience and reduce errors. Simply dialing in a procedure which tells IMAGEnet™ Professional what captures procedure is open, what angle has been chosen and which eye is being photographed.

IMAGEnet™ Professional's cutting edge and comprehensive patient database management system features efficient data viewing, storage, analysis and flexible networking solutions. With its unique utilities; such as PDT, AutoMosaic, stereo functionality, patient consultation, streamlines exam analysis and enhances communication with the patient.
IMAGEnet new Features
IMAGEnet™ Professional offers additional software features such as AutoMosaic, PDT, stereo and patient consultation.
AutoMosaic
A panoramic view of the retina is seamlessly stitched together using AutoMosaic software. Using a special algorithm to detect vessel edges, fields taken at random are automatically arranged in their correct positions without user intervention.

PDT/MPS measurement software
Time series observation and measurement is frequently performed before and after PDT. This provides easy to use solution and reliable result for GLD and treatment spot size description.

| Angle of coverage | 50° * in IA photography (only in Type IA), photography can be done only in 50° |
|---|---|
| 45° * When the digital single-lens reflex camera (commercially available product) can be installed, photography can be done only in 45° |
|
| 30° * 30°and 45°are recommended for non-mydriatic photography. |
|
| Possible photography pupil diameter | Angle of coverage 50°: φ5.5mm or more |
| Angle of coverage 45°: φ4.5mm or more | |
| Angle of coverage 30°: φ4.0mm or more | |
| Types of photography | Color, FA, blue filter, IA *, red free *Only in Type IA |
| Focus range to compensate the refractive errors of the patient's eye | 0: -13D to +12D *The area where the split lines are used. |
| -: -33D to -12D | |
| +: +9D to +40D | |
| Internal fixation target Angle of coverage: only 45°and 30°for infrared observation |
Center: 4 fixed points (Performs the link operation with right/left eye detection and the picture angle detection.) Periphery: 8 fixed points |
| External fixation target | Only used in visible observation |
| Working range | 40.7mm |
| Base movement |
Back-and-fourth: 80mm Right-and-left: 110mm Fine movement: 12mm Up-and-down: 30mm |
| Base swing angle | Right and left: 32.5° |
| Up-and-down inclined angle | Upper 15°/ Lower 10° |
| Chinrest movement | 60mm |
| Source voltage | AC 100-120/220-240VA, 50-60Hz |
| Power input | 1500VA |
| Dimensions | 340(W)mm × 505(D)mm × 535~800(H)mm |
| Weight | 35.9kg (When the digital photography unit is built in) |
| 35.7kg (When the digital single-lens reflex camera (commercially available product) can be installed.) |