3D OCT-2000 series was designed to meet the needs of all eye care professionals
The 3D OCT 2000 series of spectral domain OCTs was designed to meet the needs of all eye care professionals- from the single doctor practice to a large university hospital there is a model of the 3D OCT 2000 to meet everyone’s needs.
- 3D OCT-2000 FA plus
-

-
OCT, Color,
Red-free(Digital), FA, FAF images acquirable
- 3D OCT-2000 FA
-

-
OCT, Color,
Red-free(Digital), FA images acquirable
- 3D OCT-2000
-

-
OCT, Color,
Red-free(Digital) images acquirable
12×9mm Wide Scan
The new 12×9mm wide scan enables the user to capture a wider range of the image from optic disc to macula
with a single shot. With this 12mm wide range, you can easily observe the extent of temporal RNFL loss,
and the vertical scanning will let you intuitively detect an asymmetrical part of the tomogram which is especially
useful in detecting early glaucoma.This new capturing pattern will strongly enhance your clinic workflow and
reduce patient fatigue.

Easy Operation
Topcon 3D OCT allows high-resolution visualization of retinal layers and crystal clear fundus image with simple navigation.

The monitor screen is a touch panel. The monitor displays information, and you can perform a variety of operations by touching its screen.

Specifications
| Observation & Photography of Fundus Image | ||
|---|---|---|
| Scan Mode | Color, FA*, FAF**(Spaide Filters), Red-free*** | |
| Observation | Near IR | |
| Picture Angle |
45° Equivalent 30° (Digital Zoom) |
|
| Diopter Scale Range**** | -13D to +12D (in fundus photography) | |
| Operating Distance |
40.7mm (in fundus photography) 63.7mm (in anterior segment photography)***** |
|
| Photographable Diameter of Pupil |
45°:φ4.0mm or more Small pupil diameter:φ3.3mm or more |
|
| Observation & Photography of Fundus Image / Anterior Segment Tomogram | ||
| Scanning Range | (On Fundus) |
[Lateral] within 3~9mm [Vertical] within 3~9mm |
| (On Cornea) |
[Lateral] within 3~6mm [Vertical] within 3~6mm |
|
|
Scan Patterns****** (Recommended) |
Macula: 3D Scan | 512×128 (128 horizontal scan lines comprised of 512 A-scans), 6×6mm |
| Macula: Radial Scan | 1024×6 or 12 (6 or 12 radial scan lines comprised of 1024 A-scans), 6mm | |
| Macula: 7 Line Raster | 1024×7 (1024 A-scans per B-scan×7) , 6mm | |
| Disc: 3D Scan | 512×128 (128 horizontal scan lines comprised of 512 A-scans), 6×6mm | |
| Disc: Circle Scan | 1024 A-scans, φ3.4mm | |
|
Anterior: Radial Scan (For Cornea) |
1024×12 (12 radial scan lines comprised of 1024 A-scans), 6mm | |
|
Anterior: Line Scan (For Angle Chamber) |
1024 (line scan line comprised of 1024 A-scans), 3mm | |
| Scan Speed | 50,000 A-scans per second / 27,000 A-scans per second | |
| Scan Depth | 2.3mm | |
| In-depth Resolution | 5μm ~ 6μm | |
| Photographable Diameter of Pupil | φ2.5mm or more | |
| Observation & Photography of Fundus Image / Fundus Tomogram | ||
| Retinal Layers Identified |
Macula: ILM, IS/OS, RPE, BM Glaucoma: ILM, NFL, IPL |
|
| OCT Reference Focus | Vitreous and Choroid | |
| Fixation |
Adjustable internal matrix LCD and external fixation device (Matrix LCD :The display position can be changed and adjusted. The presenting method can be changed.) |
|
| Light Source / Power Source / Power Supply | ||
| Light Source |
Super Iuminescence diode(SLD) Wavelength 840nm Half Bandwidth:50nm Output on cornea ≤ 0.65 mW |
|
| Power Source |
Voltage: 100/110/120/220/230/240V Frequency: 50-60Hz |
|
| Power Supply | 200VA (Max 400VA) | |
| Dimensions / Weight | ||
| Dimensions | 545mm(W)×535mm(D)×600~630mm(H) | |
| Weight |
35kg (3D OCT-2000) 36kg (3D OCT-2000 FA) 37kg (3D OCT-2000 FA plus) |
|
* Only for FA and FA plus models
** Only for FA plus model
*** Display digital Red-free
**** Without the diopter compensation
***** With anterior segment attachment
****** More variable scan patterns available with a combination of different pixel and scan range.
※ Please check with local Topcon dealer for PC specification.