Diagnostic
Non Mydriatic Retinal Camera TRC-NW8F plus

Multi Function Retinal Camera TRC-NW8F plus        

gantei4shu.jpg

8Fplusgaikan_eng.jpg

Color, Red-free, Fluorescein Angiography and Spaide Fundus AutoFluorescence (FAF) imaging provides a wide range of imaging modalities to meet the needs of most of eye care facilities!  The TRC-NW8F plus features many automatic features to makeit easy to operate.           A new low intensity flash increases patient comfort.

Features
Multi Function Retinal Camera
Auto Focus and Auto Capture
Automatic Small Pupil Detection
Easy to Use
Exclusive Spaide FAF Filters
Continuous Capturing Function
Low Flash Intensity
Space-saving Compact Design

* Digital Red-free  ** Image courtesy of Oogkliniek, Deurne

Easy to Use

 

Auto Focus and Auto Capture
The TRC-NW8F plus is built for ease of operation and durability. Topcon’s ample experience in the manufacturing of
retinal cameras make it possible to bring all the benefits of non-mydriatic and mydriatic imaging into a single compact
instrument. The Auto Focus and Auto Capture functions can be switched to manual operation if necessary.
AutoShoot.jpg

Auto Small Pupil Detection
In patients with small pupils the automatic small pupil detection feature
permits capturing images through pupils as small as 3.3mm in diameter.

shoudoukoujidoukennti.jpg


Low Flash Intensity
Patient comfort and minimizing the side effects of flash illumination have always been Topcon’s concerns.
The TRC-NW8F plus can capture images using 50% of
the flash intensity used in conventional models.

One Touch Operation
Different modes of capture (color, Red-free, FA, FAF)
can be easily activated either by pressing a switch or
sliding a filter lever.


Stereo Photography
With just one touch of the stereo switch, stereo capture
is activated. The instrument automatically sets for two
consecutive images to be obtained with just the right
amount of shift for consistent and reproducible stereo
viewing. The stereo pair can be viewed with IMAGEnet R4.
Stereo.jpg

 

High Quality Image

Image Quality and Durability: Two Very Important Features
With these requirements in mind Topcon selected one of the most reputable brands of digital SRL cameras
to be used as the capturing sensor of the TRC-NW8F plus. This choice ensures continuity and consistency
in the quality of images regardless of the changes in technology.

shourei_3.jpg

Fluorescein Angiography
The TRC-NW8F plus makes fluorescein angiography simple for the operator and comfortable for the patient.
The low intensity flash enhances patient cooperation and the ergonomically located controls simplify the
photographer’s task.
FA_phase4.jpg

 


Exclusive Spaide Fundus AutoFluorescence
Built in AutoFluorescence filters allow for easy capture
of FAF images for observation of Lipofucin deposits in
the retinal pigment epithelium. The exclusive Spaide FAF
filters are the result of several years of research and
are more efficient than previous filters, requiring less
illumination and yielding better contrast.
FAF.jpg
 

Imaging System


IMAGEnetTM R4
IMAGEnetTM R4’s cutting edge and comprehensive patient database managementsystem features efficient data viewing, storage, analysis and flexible networking solutions.
With its unique utilities, such as Auto Mosaic, stereo functionality, patient consultation, IMAGEnetTM R4 software streamlines exam analysis and enhances communication
with patient.
IMG-R4image.jpg
 

EZ CaptureTM
Simple & easy software EZ CaptureTM allows you to transfer and save retinal images with intuitive handling.
Timer, R/L eye detection, angle and patientdata will also be transferred with images.

EZcapture.jpg



Auto Mosaic Software (Optional)
A panoramic view of the retina is seamlessly stitched
together using theAuto Mosaic software.
The Auto Mosaic automatically aligns and arranges
image to provide a wide field seamless image of the retina.
AutoMosaic.jpg

 

Specifications


Picture angle 45° 30°
Working distance 40.7mm
Photographable area of pupil
 
Φ4.0mm or more
Φ3.3mm or more when the small pupil diaphragm is used
Type of photography Color photography, Red-free photography**,  FA photography and FAF photography
Focus range to correct the
refractive errors of the patient's eye
Without correction lens:-13D to +12D***
With minus correction lens: -33D to -12D
With plus correction lens: +9D to +40D
Auxiliary function for photography Auto focus function
(Used only within the split line working range. This function can be turned ON / OFF.)
Fixation target Internal / External fixation target can be selected.
Internal fixation target :
  Center / Periphery
  Right / Left eye automatic detection
  Optional position presetting function
Base movement Back-forth:46mm, Right-left:100mm, Up-down:30mm
Chinrest movement 67mm
Power source Frequency : 50 / 60Hz     Voltage : AC100-240V
Weight 23.8kg (Without external fixation target)
Dimensions 274(W) X 508(D) X 536-566(H)mm
Power consumptions 400VA(Maximum), 100VA(Normal)
*      Digital Zoom
**     Digital Red-free
***   Split line working range


Optional Accessory
External Fixation Target
option.jpg